CoolProp: HOWTO reproduce a pressure vs specific enthalpy chart in Mathematica. Example: R32 refrigerant.
Mathematica: MTools: Argument pattern matching does not respect inheritance (undermines design-by-contract and heaps of Design Patterns)
Wolfram Workbench for Mathematica: Limitation: Using more than one '$' sign within function names blocks navigation on function usages.
Mathematica: GOTCHA: EntityFunction can only return a scalar (although its the 3rd decade of the 21st century)
GOTCHA/BUG: Cameo Simulation Toolkit v2021xR1 + Mathematica: Delegation to Mathematica from ConstraintBlocks FAILS if any of the input or output parameters are larger than 99999 because they get interpreted as 1.0e5 and that trips something! Aarrrggggh!
Mathematica + Magic Model Analyst (Cameo Simulation Toolkit) for SysML Parametrics: GOTCHA: You must use a regular '=' on the SysML side, not the Mathematica '==' (or it will be intepreted as a constraint condition to test, not an equation to solve).
Cameo Simulation Toolkit: v19SP3: GOTCHA/BUG: When a Property is typed by an abstract Block an instance of a concrete specialising Block (where available) will automatically be created and assigned even when the lower multiplicity is 0
TIP/GOTCHA: MagicDraw SysML/Cameo: In Parametric Diagrams create BindingConnectors involving part properties by selecting the constraint parameter symbol first and use the smart manipulator (otherwise you might accidentally create a regular Connector)
UML/SysML: MagicDraw/Cameo 19SP3: GOTCHA/TIP: An Instance Table will not display a row for instances typed by an abstract Class/Block (although one can show such instances as InstanceSpecification symbols on a Class Diagram or Block Definition Diagram)
UML/SysML: Cameo Simulation Toolkit 19SP3: GOTCHA/TIP: ConstraintBlock constraints: Not every available constraint language can handle Enumeration literals (if in doubt choose 'English')
UML: Cameo Simulation Toolkit 19SP3: GOTCHA: CreateObjectAction ignores an Artifact as 'classifier' even though Artifact is a Classifier
GOTCHA: UML/SysML: Cameo Simulation Toolkit 19SP3: A [true] or [false] guard on an ActivityEdge MUST be a LiteralBoolean, not just characters typed in, or the evaluation may give unexpected or ill-defined results
UML/SysML: Cameo Simulation Toolkit 19SP3: A parent Activity with a DecisionNode that uses a Activity as a decisionInput Behavior terminates immediately after the decisionInput terminates (but OpaqueBehavior works)
UML/SysML: Cameo Simulation Toolkit 19SP3: GOTCHA: Will not evaluate a guard using a token from a decisionInputFlow UNLESS a decisionInput Behaviour is explicitly defined (but Alf does)
UML/SysML: MagicDraw/Cameo: WARNING: If you assign a value to a Slot for an untyped Property then assign a ValueType later it will DELETE your assigned value! Assign a type first .
MagicDraw/Cameo v19SP3: vs SysPhS-1.1: OpaqueExpression for Slot value exports to Modelica as 'null' if only uses a single variable. WORKAROUND/HACK prefix the variable with '1 *' [FIXED in v2021x]
SysML vs Modelica: GOTCHA: Terminology: A 'connector' in Modelica is equivalent to the Type of a Port in SysML. A Connector in SysML-1.x is equivalent to a 'connect(source,target)' in Modelica.
MagicDraw/Cameo v19SP3+SysPhS-1.1: Does not cleanly export INLINE Modelica 'if/then/else' statements (a.k.a. "switching" form)
MagicDraw/Cameo: GOTCHA: When applying a numerical default to a value property make sure the value property has already been typed by Real or Integer (or a ValueType that extends one of them) otherwise it will assign a LiteralString as default.
SysPhSLibrary and ISO-80000 ModelLibrary: Some ValueType names and Unit symbols are not Modelica-friendly
MagicDraw/Cameo v19SP3: SysPhS: If you have a custom ValueType it MUST extend Real either directly or indirectly or it will not be seen on export to Modelica.
MagicDraw SysML/Cameo: If you have a SINGLE Allocate from an Activity to a Block it will set that Block to be the Behavior::/context for that Activity.
SysML: The placement of usages of Blocks, their Ports, and Connectors in an Internal Block Diagrams DOES NOT necessarily represent physical geometry!
GOTCHA: MagicDraw SysML/Cameo 19SP3: Export to Modelica: The name of a redefining Property must be exactly the same as the Property it redefines or it will not export properly!
Wolfram SystemModeler: On Mac the Unit Conversions dialog is under SystemModeler -> Preferences -> Global -> Unit Conversion (rather than under Tools -> Options)
Wolfram SystemModeler: GOTCHA: The conversion dialog will not offer the Add Unit Conversion button unless there is not already an existing conversion in BOTH directions.
MagicDraw/Cameo: If you drag a Behavior from the model browser onto the SYMBOL of a State (that does not already own the Behavior) and set it as an 'entry', 'doActivity', or 'exit' Behavior a "wrapper" Behavior owned by the State will be created.
MagicDraw SysML/Cameo 19SP3: GOTCHA: If you drag a Behavior from the model browser onto the 'entry', 'doActivity', or 'exit' field in a specification dialog of a State it WILL BECOME OWNED by the State (which "steals ownership")!
Modelica does not support comparison of Real values using == outside of functions (so not directly inside state machines)
MagicDraw/Cameo v19SP3 vs SysML&SysPhS: GOTCHA: Will NOT correctly export a SysML-1.6 «~interfaceBlock» to Modelica (but does cope with a tilde ~ prefix in the name of a plain InterfaceBlock)
MagicDraw/Cameo vs SysML&SysPhS: GOTCHA: Will NOT export a non-normative System «system» block to Modelica, it only recognises a plain Block «block»!